MONOESTÁVEIS |
 |
POK |
BIPOK |
TRIPOK |
2
inverter contacts 5 A |
4
inverter contacts 5 A |
6 inverter
contacts 5 A |
| DC coil control |
| Nominal voltage (Um) |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
| Woking voltage |
80%
~ 115% |
80%
~ 115% |
80%
~ 115% |
| Consumption |
2,5W |
3,0W |
3,5W |
| AC
coil control |
| Nominal voltage |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
| Woking voltage |
85%
~110% |
85%
~110% |
85%
~110% |
| Consumption |
4,0VA |
4,0VA |
5,5VA |
| Contacts |
| Number and type |
2
changeover |
4
changeover |
6
changeover |
| Max cut-out |
5A
continuous |
5A
continuous |
5A
continuous |
| Max transient current |
100A
for 10ms |
100A
for 10ms |
100A
for 10ms |
| Pressure of make contact |
|
|
|
| Pressure of break contact |
|
|
|
| Make time Un dc |
20
ms |
20
ms |
20
ms |
| Make / break Un ac |
20
ms |
20
ms |
20
ms |
| Break time Un dc |
15
ms |
15
ms |
15
ms |
| Make / break Un ac |
20
ms |
20
ms |
20
ms |
| Mechanics
and environment |
| Coil-contact dielectric strengt |
2KV
for 1 min. |
2KV
for 1 min. |
2KV
for 1 min. |
| Contact- contact dielectric strengt |
1KV for 1 |
1KV for 1 |
1KV for 1 |
| Isolation resistence |
>1000Mohm
to 500VDC |
>1000Mohm
to 500VDC |
>1000Mohm
to 500VDC |
| Mechanical life |
20.000.000operations |
20.000.000operations |
20.000.000operations |
| Environmental conditions (tropicalised version) |
P2:
coil tropicalised
( 50°C with 95% HR) |
P2:
coil tropicalised
( 50°C with 95% HR) |
P2:
coil tropicalised
( 50°C with 95% HR) |
| Vibration resistance |
5g
from 10 to 55Hz |
5g
from 10 to 55Hz |
5g
from 10 to 55Hz |
| Shock resistence |
20g
for 11ms |
20g
for 11ms |
20g
for 11ms |
| Weight |
90gr. |
170gr. |
250gr. |
| Options |
|
|
|
| Accessories |
|
|
|
| |
|
|
|
MONOESTÁVEIS |
 |
POKS |
BIPOKS |
TRIPOKS |
2 inverter contacts 10A |
4 inverter
contacts 10A |
6 inverter contacts 10 A |
| DC
coil control |
| Nominal voltage (Um) |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
| Woking voltage |
80%
~ 115% |
80%
~ 115% |
80%
~ 115% |
| Consumption |
2,5W |
3,0W |
3,5W |
| AC
coil control |
| Nominal voltage |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
| Woking voltage |
85%
~110% |
85%
~110% |
85%
~110% |
| Consumption |
4,0VA |
4,0VA |
5,5VA |
| Contacts |
| Number and type |
2
changeover |
4
changeover |
6
changeover |
| Max cut-out |
10A
continuous |
10A
continuous |
10A
continuous |
| Max transient current |
150A
for 10ms |
150A
for 10ms |
150A
for 10ms |
| Pressure of make contact |
|
|
|
| Pressure of break contact |
|
|
|
| Make time Un dc |
20
ms |
20
ms |
20
ms |
| Make / break Un ac |
20
ms |
20
ms |
20
ms |
| Break time Un dc |
15
ms |
15
ms |
15
ms |
| Make / break Un ac |
20
ms |
20
ms |
20
ms |
| Mechanics
and environment |
| Coil-contact dielectric strengt |
2KV
for 1min. |
2KV
for 1min. |
2KV
for 1min. |
| Contact- contact dielectric strengt |
1KV for 1 |
1KV for 1 |
1KV for 1 |
| Isolation resistence |
>1000Mohm
to 500VDC |
>1000Mohm
to 500VDC |
>1000Mohm
to 500VDC |
| Mechanical life |
20.000.000operations |
20.000.000operations |
20.000.000operations |
| Environmental conditions (tropicalised version) |
P2:
coil tropicalised
( 50°C with 95% HR) |
P2:
coil tropicalised
( 50°C with 95% HR) |
P2:
coil tropicalised
( 50°C with 95% HR) |
| Vibration resistance |
5g
from 10 to 55Hz |
5g
from 10 to 55Hz |
5g
from 10 to 55Hz |
| Shock resistence |
20g
for 11ms |
20g
for 11ms |
20g
for 11ms |
| Weight |
90gr. |
170gr. |
250gr. |
| Options |
|
|
|
| Accessories |
|
|
|
| |
|
|
|
MONOESTÁVEIS |
 |
DOPPIO
BIPOK |
DOPPIO
BIPOKS |
DOPPIO
TRIPOK |
8 inverter contacts 5 A |
8 inverter
contacts 10A |
12 inverter contacts 5A |
| DC
coil control |
| Nominal voltage (Um) |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
| Woking voltage |
80%
~115% |
80%
~115% |
80%
~115% |
| Consumption |
6,0W |
6,0W |
7,0W |
| AC
coil control |
| Nominal voltage |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
12-24-48-110-125-220 |
| Woking voltage |
85%
~110% |
85%
~110% |
85%
~110% |
| Consumption |
8,0VA |
8,0VA |
11,0VA |
| Contacts |
| Number and type |
8
changeover |
8
changeover |
12
changeover |
| Max cut-out |
5A
continuous |
10A
continuous |
5A
continuous |
| Max transient current |
100A
for 10ms |
150A
for 10ms |
100A
for 10ms |
| Pressure of make contact |
|
|
|
| Pressure of break contact |
|
|
|
| Make time Un dc |
20
ms |
20
ms |
20
ms |
| Make / break Un ac |
20
ms |
20
ms |
20
ms |
| Break time Un dc |
15
ms |
15
ms |
15
ms |
| Make / break Un ac |
20
ms |
20
ms |
20
ms |
| Mechanics
and environment |
| Coil-contact dielectric strengt |
2KV
for 1 min. |
2KV
for 1 min. |
2KV
for 1 min. |
| Contact- contact dielectric strengt |
1KV
for 1 min. |
1KV
for 1 min. |
1KV
for 1 min. |
| Isolation resistence |
>1000Mohm
to 500Vdc |
>1000Mohm
to 500Vdc |
>1000Mohm
to 500Vdc |
| Mechanical life |
20.000.000
operations |
20.000.000
operations |
20.000.000
operations |
| Environmental conditions (tropicalised version) |
P2:
coil tropicalised
( 50°C with 95%HR ) |
P2:
coil tropicalised
( 50°C with 95%HR ) |
P2:
coil tropicalised
( 50°C with 95%HR ) |
| Vibration resistance |
5g
from 10 to 55 Hz |
5g
from 10 to 55 Hz |
5g
from 10 to 55 Hz |
| Shock resistence |
20g
for 11 ms |
20g
for 11 ms |
20g
for 11 ms |
| Weight |
340gr |
340gr |
520gr |
| Options |
|
|
|
| Accessories |
|
|
|
| |
|
|
|
MONOESTÁVEIS |
 |
DOPPIO
TRIPOKS |
|
| 12 inverter contacts 10A |
| DC
coil control |
| Nominal voltage (Um) |
12-24-48-110-125-220 |
|
| Woking voltage |
80%
~115% |
| Consumption |
7,0W |
| AC
coil control |
| Nominal voltage |
12-24-48-110-125-220 |
|
| Woking voltage |
85%
~ 110% |
| Consumption |
11,0VA |
| Contacts |
| Number and type |
12
changeover |
|
| Max cut-out |
5A
continuous |
| Max transient current |
100A
for 10ms |
| Pressure of make contact |
|
| Pressure of break contact |
|
| Make time Un dc |
20
ms |
| Make / break Un ac |
20
ms |
| Break time Un dc |
15
ms |
| Make / break Un ac |
20
ms |
| Mechanics
and environment |
| Coil-contact dielectric strengt |
2KV
for 1 min. |
|
| Contact- contact dielectric strengt |
1KV
for 1 min. |
| Isolation resistence |
>1000Mohm
to 500Vdc |
| Mechanical life |
20.000.000
operations |
| Environmental conditions (tropicalised version) |
P2:
coil tropicalised
( 50°C with 95%HR ) |
| Vibration resistance |
5g
from 10 to 55 Hz |
| Shock resistence |
20g
for 11 ms |
| Weight |
520gr |
| Options |
|
| Accessories |
|
| |
|