MONOESTÁVEIS
POK BIPOK TRIPOK

2 inverter contacts 5 A

4 inverter contacts 5 A

6 inverter contacts 5 A
DC coil control
Nominal voltage (Um)
Woking voltage
Consumption
12-24-48-110-125-220
80% ~ 115%
2,5W
12-24-48-110-125-220
80% ~ 115%
3,0W
12-24-48-110-125-220
80% ~ 115%
3,5W
AC coil control
Nominal voltage
Woking voltage
Consumption
12-24-48-110-125-220
85% ~ 110%
4,0VA
12-24-48-110-125-220
85% ~ 110%
4,0VA
12-24-48-110-125-220
85% ~ 110%
5,5VA
Contacts
Number and type
Max cut-out
Max transient current
Pressure of make contact
Pressure of break contact
Make time Un dc
Make / break Un ac
Break time Un dc
Make / break Un ac
2 changeover
5A continuous
100A for 10 ms


20 ms
20 ms
15 ms
20 ms
4 changeover
5A continuous
100A for 10 ms


20 ms
20 ms
15 ms
20 ms
6 changeover
5A continuous
100A for 10 ms


20 ms
20 ms
15 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
Contact- contact dielectric strengt
Isolation resistence
Mechanical life
Environmental conditions (tropicalised version)

Vibration resistance
Shock resistence
Weight
Options
Accessories
2KV for 1min.
1KV for 1 min.
>1000Mohm to 500VDC
20.000.000operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
90 gr.
2KV for 1min.
1KV for 1 min.
>1000Mohm to 500VDC
20.000.000operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
170 gr.
2KV for 1min.
1KV for 1 min.
>1000Mohm to 500VDC
20.000.000operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
250 gr.

Voltar


MONOESTÁVEIS
POKS BIPOKS TRIPOKS

2 inverter contacts 10A

4 inverter contacts 10A

6 inverter contacts 10A
DC coil control
Nominal voltage (Um)
Woking voltage
Consumption
12-24-48-110-125-220
80% ~ 115%
2,5W
12-24-48-110-125-220
80% ~ 115%
3,0W
12-24-48-110-125-220
80% ~ 115%
3,5W
AC coil control
Nominal voltage
Woking voltage
Consumption
12-24-48-110-125-220
85% ~ 110%
4,0VA
12-24-48-110-125-220
85% ~ 110%
4,0VA
12-24-48-110-125-220
85% ~ 110%
5,5VA
Contacts
Number and type
Max cut-out
Max transient current
Pressure of make contact
Pressure of break contact
Make time Un dc
Make / break Un ac
Break time Un dc
Make / break Un ac
2 changeover
10A continuous
150A for 10 ms


20 ms
20 ms
15 ms
20 ms
4 changeover
10A continuous
150A for 10 ms


20 ms
20 ms
15 ms
20 ms
6 changeover
10A continuous
150A for 10 ms


20 ms
20 ms
15 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
Contact- contact dielectric strengt
Isolation resistence
Mechanical life
Environmental conditions (tropicalised version)

Vibration resistance
Shock resistence
Weight
Options
Accessories
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500VDC
20.000.000operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
90 gr.
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500VDC
20.000.000operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
170 gr.
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500VDC
20.000.000operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
250 gr.

Voltar


MONOESTÁVEIS
DOPPIO BIPOK DOPPIO BIPOKS DOPPIO TRIPOK

8 inverter contacts 5A

8 inverter contacts 10A

12 inverter contacts 5A
DC coil control
Nominal voltage (Um)
Woking voltage
Consumption
12-24-48-110-125-220
80% ~ 115%
6,0W
12-24-48-110-125-220
80% ~ 115%
6,0W
12-24-48-110-125-220
80% ~ 115%
7,0W
AC coil control
Nominal voltage
Woking voltage
Consumption
12-24-48-110-125-220
85% ~ 110%
8,0VA
12-24-48-110-125-220
85% ~ 110%
8,0VA
12-24-48-110-125-220
85% ~ 110%
11,0VA
Contacts
Number and type
Max cut-out
Max transient current
Pressure of make contact
Pressure of break contact
Make time Un dc
Make / break Un ac
Break time Un dc
Make / break Un ac
8 changeover
5A continuous
100A for 10 ms


20 ms
20 ms
15 ms
20 ms
8 changeover
10A continuous
150A for 10 ms


20 ms
20 ms
15 ms
20 ms
12 changeover
5A continuous
100A for 10 ms


20 ms
20 ms
15 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
Contact- contact dielectric strengt
Isolation resistence
Mechanical life
Environmental conditions (tropicalised version)

Vibration resistance
Shock resistence
Weight
Options
Accessories
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
340 gr.
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
340 gr.
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
520 gr.

Voltar
MONOESTÁVEIS
DOPPIO TRIPOKS
12 inverter contacts 10A
DC coil control
Nominal voltage (Um)
Woking voltage
Consumption
12-24-48-110-125-220
80% ~ 115%
7,0W
AC coil control
Nominal voltage
Woking voltage
Consumption
12-24-48-110-125-220
85% ~ 110%
11,0VA
Contacts
Number and type
Max cut-out
Max transient current
Pressure of make contact
Pressure of break contact
Make time Un dc
Make / break Un ac
Break time Un dc
Make / break Un ac
12 changeover
5A continuous
100A for 10 ms


20 ms
20 ms
15 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
Contact- contact dielectric strengt
Isolation resistence
Mechanical life
Environmental conditions (tropicalised version)

Vibration resistance
Shock resistence
Weight
Options
Accessories
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
520 gr.
Voltar