MONOESTÁVEIS
OKSFC OKSCd OKUIC

4 inverter contacts 10A

4 inverter contacts 10A

4 inverter contacts 10A
DC coil control
Nominal voltage (Um)
Woking voltage



Consumption
12-24-48-110-125-220
80% ~ 120%



3,5W
12-24-48-110-125-220
80% ~ 120%



5,0W
24-72-110-128
24VDC ( 18 ~ 33 )VDC
72VDC ( 55 ~ 110 )VDC
110VDC ( 77~144 )VDC
128VDC ( 85~160 )VDC
3,5W
AC coil control
Nominal voltage
Woking voltage
Consumption
12-24-48-110-125-220
85% ~ 115%
3,5W
12-24-48-110-125-220
85% ~ 115%
5,0W
ONLY DC
ONLY DC
ONLY DC
Contacts
Number and type
Max cut-out
Max transient current
Pressure of make contact
Pressure of break contact
Make time Un dc
Make / break Un ac
Break time Un dc
Make / break Un ac
4 changeover
10A continuous
150 for 10 ms


38 ms
40 ms
18 ms
80 ms
4 changeover
10A continuous
250 for 10 ms


28 ms
40 ms
20 ms
70 ms
4 changeover
10A continuous
150A for 10 ms


40 ms

18 ms

Mechanics and environment
Coil-contact dielectric strengt
Contact- contact dielectric strengt
Isolation resistence
Mechanical life
Environmental conditions (tropicalised version)
Vibration resistance
Shock resistence
Weight
Options
Accessories
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
300 gr.
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
300 gr.
2KV for 1min.
1KV for 1min.
>1000 Mohm to 500VDC
20.000.000 operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
300 gr.

Voltar