| MONOESTÁVEIS |
|
OKSFC |
OKSCd |
OKUIC |
|
4 inverter contacts 10A |
4 inverter contacts 10A |
4 inverter contacts 10A |
| DC coil control |
Nominal voltage (Um)
Woking voltage
Consumption |
12-24-48-110-125-220
80% ~ 120%
3,5W
|
12-24-48-110-125-220
80% ~ 120%
5,0W
|
24-72-110-128
24VDC ( 18 ~ 33 )VDC
72VDC ( 55 ~ 110 )VDC
110VDC ( 77~144 )VDC
128VDC ( 85~160 )VDC
3,5W |
| AC coil control |
Nominal voltage
Woking voltage
Consumption |
12-24-48-110-125-220
85% ~ 115%
3,5W
|
12-24-48-110-125-220
85% ~ 115%
5,0W
|
ONLY DC
ONLY DC
ONLY DC |
| Contacts |
Number and type
Max cut-out
Max transient current
Pressure of make contact
Pressure of break contact
Make time Un dc
Make / break Un ac
Break time Un dc
Make / break Un ac
|
4 changeover
10A continuous
150 for 10 ms
38 ms
40 ms
18 ms
80 ms
|
4 changeover
10A continuous
250 for 10 ms
28 ms
40 ms
20 ms
70 ms
|
4 changeover
10A continuous
150A for 10 ms
40 ms
18 ms
|
| Mechanics and environment |
Coil-contact dielectric strengt
Contact- contact dielectric strengt
Isolation resistence
Mechanical life
Environmental conditions (tropicalised version)
Vibration resistance
Shock resistence
Weight
Options
Accessories
|
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
300 gr. |
2KV for 1 min.
1KV for 1 min.
>1000Mohm to 500Vdc
20.000.000 operations
P2: coil tropicalised ( 50°C with 95%HR )
5g from 10 to 55 Hz
20g for 11 ms
300 gr. |
2KV for 1min.
1KV for 1min.
>1000 Mohm to 500VDC
20.000.000 operations
P2: coil tropicalised ( 50°C with 95% HR )
5g from 10 to 55Hz
20g for 11 ms
300 gr. |
|