POK BIPOK TRIPOK
2 inverter contacts 5 A
4 inverter contacts 5 A 
6 inverter contacts 5 A
DC coil control
Nominal voltage (Um)
12-24-48-110-125-220
12-24-48-110-125-220
12-24-48-110-125-220
Woking voltage
80% ~ 115%
80% ~ 115%
80% ~ 115%
Consumption
2,5W
3,0W
3,5W
AC coil control 
Nominal voltage
12-24-48-110-125-220
12-24-48-110-125-220
12-24-48-110-125-220
Woking voltage
85% ~110%
85% ~110%
85% ~110%
Consumption
4,0VA
4,0VA
5,5VA
Contacts
Number and type
2  changeover
4  changeover
6  changeover
Max cut-out
5A continuous
5A continuous
5A continuous
Max transient current
100A for 10ms
100A for 10ms
100A for 10ms
Pressure of make contact      
Pressure of break contact      
Make time Un dc
20 ms
20 ms
20 ms
Make / break Un ac
20 ms
20 ms
20 ms
Break time Un dc
15 ms
15 ms
15 ms
Make / break Un ac
20 ms
20 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
2KV for 1 min.
2KV for 1 min.
2KV for 1 min.
Contact- contact dielectric strengt
1KV for 1 
1KV for 1 
1KV for 1 
Isolation resistence
>1000Mohm to 500VDC
>1000Mohm to 500VDC
>1000Mohm to 500VDC
Mechanical life
20.000.000operations
20.000.000operations
20.000.000operations
Environmental conditions (tropicalised version)
P2: coil tropicalised
( 50°C with 95% HR)
P2: coil tropicalised
( 50°C with 95% HR)
P2: coil tropicalised
( 50°C with 95% HR)
Vibration resistance
5g from 10 to 55Hz
5g from 10 to 55Hz
5g from 10 to 55Hz
Shock resistence 
20g for 11ms
20g for 11ms
20g for 11ms
Weight
90gr.
170gr.
250gr.
Options
Accessories
 

Voltar


MONOESTÁVEIS
POKS BIPOKS TRIPOKS
2 inverter contacts 10A
4 inverter contacts 10A 
6 inverter contacts 10 A
DC coil control
Nominal voltage (Um)
12-24-48-110-125-220
12-24-48-110-125-220
12-24-48-110-125-220
Woking voltage
80% ~ 115%
80% ~ 115%
80% ~ 115%
Consumption
2,5W
3,0W
3,5W
AC coil control 
Nominal voltage
12-24-48-110-125-220
12-24-48-110-125-220
12-24-48-110-125-220
Woking voltage
85% ~110%
85% ~110%
85% ~110%
Consumption
4,0VA
4,0VA
5,5VA
Contacts
Number and type
2  changeover
4  changeover
6  changeover
Max cut-out
10A continuous
10A continuous
10A continuous
Max transient current
150A for 10ms
150A for 10ms
150A for 10ms
Pressure of make contact      
Pressure of break contact      
Make time Un dc
20 ms
20 ms
20 ms
Make / break Un ac
20 ms
20 ms
20 ms
Break time Un dc
15 ms
15 ms
15 ms
Make / break Un ac
20 ms
20 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
2KV for 1min.
2KV for 1min.
2KV for 1min.
Contact- contact dielectric strengt
1KV for 1 
1KV for 1 
1KV for 1 
Isolation resistence
>1000Mohm to 500VDC
>1000Mohm to 500VDC
>1000Mohm to 500VDC
Mechanical life
20.000.000operations
20.000.000operations
20.000.000operations
Environmental conditions (tropicalised version)
P2: coil tropicalised
( 50°C with 95% HR)
P2: coil tropicalised
( 50°C with 95% HR)
P2: coil tropicalised
( 50°C with 95% HR)
Vibration resistance
5g from 10 to 55Hz
5g from 10 to 55Hz
5g from 10 to 55Hz
Shock resistence 
20g for 11ms
20g for 11ms
20g for 11ms
Weight
90gr.
170gr.
250gr.
Options
Accessories
 

Voltar


 MONOESTÁVEIS
DOPPIO BIPOK DOPPIO BIPOKS DOPPIO TRIPOK
8 inverter contacts 5 A
8 inverter contacts 10A 
12 inverter contacts 5A
DC coil control
Nominal voltage (Um)
12-24-48-110-125-220
12-24-48-110-125-220
12-24-48-110-125-220
Woking voltage
80% ~115%
80% ~115%
80% ~115%
Consumption
6,0W
6,0W
7,0W
AC coil control 
Nominal voltage
12-24-48-110-125-220
12-24-48-110-125-220
12-24-48-110-125-220
Woking voltage
85% ~110%
85% ~110%
85% ~110%
Consumption
8,0VA
8,0VA
11,0VA
Contacts
Number and type
8 changeover
8 changeover
12 changeover
Max cut-out
5A continuous
10A continuous
5A continuous
Max transient current
100A for 10ms
150A for 10ms
100A for 10ms
Pressure of make contact      
Pressure of break contact      
Make time Un dc
20 ms
20 ms
20 ms
Make / break Un ac
20 ms
20 ms
20 ms
Break time Un dc
15 ms
15 ms
15 ms
Make / break Un ac
20 ms
20 ms
20 ms
Mechanics and environment
Coil-contact dielectric strengt
2KV for 1 min.
2KV for 1 min.
2KV for 1 min.
Contact- contact dielectric strengt
1KV for 1 min.
1KV for 1 min.
1KV for 1 min.
Isolation resistence
>1000Mohm to 500Vdc
>1000Mohm to 500Vdc
>1000Mohm to 500Vdc
Mechanical life
20.000.000 operations
20.000.000 operations
20.000.000 operations
Environmental conditions (tropicalised version)
P2: coil tropicalised
( 50°C with 95%HR )
P2: coil tropicalised
( 50°C with 95%HR )
P2: coil tropicalised
( 50°C with 95%HR )
Vibration resistance
5g from 10 to 55 Hz
5g from 10 to 55 Hz
5g from 10 to 55 Hz
Shock resistence 
20g for 11 ms
20g for 11 ms
20g for 11 ms
Weight
340gr
340gr
520gr
Options
Accessories
 

Voltar


MONOESTÁVEIS
DOPPIO TRIPOKS  
12 inverter contacts 10A
DC coil control
Nominal voltage (Um)
12-24-48-110-125-220
 
Woking voltage
80% ~115%
Consumption
7,0W
AC coil control 
Nominal voltage
12-24-48-110-125-220
 
Woking voltage
85% ~ 110%
Consumption
11,0VA
Contacts
Number and type
12 changeover
 
Max cut-out
5A continuous
Max transient current
100A for 10ms
Pressure of make contact  
Pressure of break contact  
Make time Un dc
20 ms
Make / break Un ac
20 ms
Break time Un dc
15 ms
Make / break Un ac
20 ms
Mechanics and environment
Coil-contact dielectric strengt
2KV for 1 min.
 
Contact- contact dielectric strengt
1KV for 1 min.
Isolation resistence
>1000Mohm to 500Vdc
Mechanical life
20.000.000 operations
Environmental conditions (tropicalised version)
P2: coil tropicalised
( 50°C with 95%HR )
Vibration resistance
5g from 10 to 55 Hz
Shock resistence 
20g for 11 ms
Weight
520gr
Options
Accessories
 

Voltar